Run an analysis from the canvas setup drawer to populate this workspace.
Path budget picker
Click a metric cell to plot that stage on the active path.
Run an analysis to populate the path budget picker.
Mixer spur plan
Every m x n product of the RF band and the LO, and every input band that lands in the IF, with the datasheet level and what your filters take off. Worked in your browser and saved with the design.
Blank fields follow the lineup: the channel at the mixer's RF port, its LO, and the IF it makes. Difference product, LO below the RF band.
Image at 1949.5 to 1950.5 MHz: 0.0 dBc, 0.0 dB of it from Preselector BPF. A scalar filter takes nothing off; give it a loss curve to count its rejection.
No product of order 5 or less lands in the 249.5 to 250.5 MHz IF.
Scroll sideways for more columns
| Spur | Input | Input (MHz) | Level (dBc) | Rejected by | Rejection (dB) | After (dBc) | In RF band |
|---|---|---|---|---|---|---|---|
| Image | LO − IF | 1949.5 to 1950.5 | 0.0 | Preselector BPF | 0.0 | 0.0 | |
| IF feedthrough | IF | 249.5 to 250.5 | no entry | Preselector BPF | 0.0 | ||
| 2x0 | (IF)/2 | 124.75 to 125.25 | no entry | Preselector BPF | 0.0 | ||
| 1x2 | 2LO + IF | 4649.5 to 4650.5 | no entry | Preselector BPF | 0.0 | ||
| 1x2 | 2LO − IF | 4149.5 to 4150.5 | no entry | Preselector BPF | 0.0 | ||
| 2x1 | (LO + IF)/2 | 1224.75 to 1225.25 | no entry | Preselector BPF | 0.0 | ||
| 2x1 | (LO − IF)/2 | 974.75 to 975.25 | no entry | Preselector BPF | 0.0 | ||
| 3x0 | (IF)/3 | 83.167 to 83.5 | no entry | Preselector BPF | 0.0 | ||
| 1x3 | 3LO + IF | 6849.5 to 6850.5 | no entry | Preselector BPF | 0.0 | ||
| 1x3 | 3LO − IF | 6349.5 to 6350.5 | no entry | Preselector BPF | 0.0 | ||
| Half-IF | (2LO + IF)/2 | 2324.75 to 2325.25 | no entry | Preselector BPF | 0.0 | ||
| 2x2 | (2LO − IF)/2 | 2074.75 to 2075.25 | no entry | Preselector BPF | 0.0 | ||
| 3x1 | (LO + IF)/3 | 816.5 to 816.833 | no entry | Preselector BPF | 0.0 | ||
| 3x1 | (LO − IF)/3 | 649.833 to 650.167 | no entry | Preselector BPF | 0.0 | ||
| 4x0 | (IF)/4 | 62.375 to 62.625 | no entry | Preselector BPF | 0.0 | ||
| 1x4 | 4LO + IF | 9049.5 to 9050.5 | no entry | Preselector BPF | 0.0 | ||
| 1x4 | 4LO − IF | 8549.5 to 8550.5 | no entry | Preselector BPF | 0.0 | ||
| 2x3 | (3LO + IF)/2 | 3424.75 to 3425.25 | no entry | Preselector BPF | 0.0 | ||
| 2x3 | (3LO − IF)/2 | 3174.75 to 3175.25 | no entry | Preselector BPF | 0.0 | ||
| 3x2 | (2LO + IF)/3 | 1549.833 to 1550.167 | no entry | Preselector BPF | 0.0 | ||
| 3x2 | (2LO − IF)/3 | 1383.167 to 1383.5 | no entry | Preselector BPF | 0.0 | ||
| 4x1 | (LO + IF)/4 | 612.375 to 612.625 | no entry | Preselector BPF | 0.0 | ||
| 4x1 | (LO − IF)/4 | 487.375 to 487.625 | no entry | Preselector BPF | 0.0 | ||
| 5x0 | (IF)/5 | 49.9 to 50.1 | no entry | Preselector BPF | 0.0 |
Levels are dBc against the wanted IF output, from the table at its reference RF level. An output product of RF order m moves (m − 1) dB per dB of RF input, scaled to -71.5 dBm at the RF port. Input spurs read the table at its own level; a stronger interferer of order m rises (m − 1) dB per dB. Rejection is each filter's curve read at the spur, worst of the band edges and centre, against its loss at the wanted frequency. A scalar filter rejects nothing.
Datasheet m x n table
Paste the spur table: rows are RF harmonics m = 0, 1, 2 and columns LO harmonics n = 0, 1, 2, in dBc below the IF output. Header rows, an index column and blanks (-, x) are fine. If your sheet prints LO harmonics as rows, read it, then swap.
No table yet, so levels show only for the 1x1 products (0 dBc).