IndieRF dB Power Converter
dBm to watts, dB, and dBFS converter
0 dBm is 1 mW, 223.6 mV rms and 106.99 dBµV into 50 Ω. Convert dBm to watts, voltage and dBµV at 50 or 75 Ω, dBFS to dBm, dBi to dBd, and bandwidth to kTB, then print the −120 to +60 dBm table or download it as a CSV.
20log and 10log table: 20·log10(5) = 13.98 dB, 10·log10(50) = 16.99 dB
Power ratios take 10·log10 and voltage or current ratios take 20·log10, so ×5 is 6.99 dB in power and 13.98 dB in voltage. 32 ratios from 0.1 to 1000. Each dB value opens the converter's ratio tab at that number.
| Ratio | Power, 10·log10 (dB) | Voltage, 20·log10 (dB) |
|---|---|---|
| ×0.1 | −10.0000 | −20.0000 |
| ×0.2 | −6.9897 | −13.9794 |
| ×0.25 | −6.0206 | −12.0412 |
| ×0.5 | −3.0103 | −6.0206 |
| ×1 | 0.0000 | 0.0000 |
| ×1.5 | +1.7609 | +3.5218 |
| ×2 | +3.0103 | +6.0206 |
| ×3 | +4.7712 | +9.5424 |
| ×4 | +6.0206 | +12.0412 |
| ×5 | +6.9897 | +13.9794 |
| ×6 | +7.7815 | +15.5630 |
| ×7 | +8.4510 | +16.9020 |
| ×8 | +9.0309 | +18.0618 |
| ×9 | +9.5424 | +19.0849 |
| ×10 | +10.0000 | +20.0000 |
| ×15 | +11.7609 | +23.5218 |
| ×20 | +13.0103 | +26.0206 |
| ×25 | +13.9794 | +27.9588 |
| ×30 | +14.7712 | +29.5424 |
| ×40 | +16.0206 | +32.0412 |
| ×50 | +16.9897 | +33.9794 |
| ×60 | +17.7815 | +35.5630 |
| ×70 | +18.4510 | +36.9020 |
| ×80 | +19.0309 | +38.0618 |
| ×90 | +19.5424 | +39.0849 |
| ×100 | +20.0000 | +40.0000 |
| ×200 | +23.0103 | +46.0206 |
| ×250 | +23.9794 | +47.9588 |
| ×300 | +24.7712 | +49.5424 |
| ×400 | +26.0206 | +52.0412 |
| ×500 | +26.9897 | +53.9794 |
| ×1000 | +30.0000 | +60.0000 |
dB, dBm, dBW, and dBFS
These four quantities share a logarithm and almost nothing else. The converter above keeps them on separate tabs so a power level is not run through a ratio formula.
- dB is a ratio. Power uses 10·log10. Voltage into a fixed resistance uses 20·log10.
- dBm is absolute power referred to 1 mW. 0 dBm = 1 mW, and P(dBm) = 10·log10(P/1 mW).
- dBW is the same power referred to 1 W. dBW = dBm − 30. 1 W is 0 dBW and 30 dBm.
- dBFS is a ratio to a converter’s full-scale code, not a power. Turning it into dBm requires that full-scale power. This tool uses a sine-wave full scale.
Watts to dBm
P(dBm) = 10·log10(P in watts) + 30. The figures below are that expression, not the 1-2-3-7-10 approximation. +43 dBm is the usual mental-math stand-in for 20 W; the exact value is 43.01 dBm.
Scroll sideways for more columns
| Power | dBm | dBW |
|---|---|---|
| 1 mW | 0.00 | -30.00 |
| 10 mW | 10.00 | -20.00 |
| 100 mW | 20.00 | -10.00 |
| 250 mW | 23.98 | -6.02 |
| 500 mW | 26.99 | -3.01 |
| 1 W | 30.00 | 0.00 |
| 2 W | 33.01 | 3.01 |
| 5 W | 36.99 | 6.99 |
| 10 W | 40.00 | 10.00 |
| 20 W | 43.01 | 13.01 |
| 25 W | 43.98 | 13.98 |
| 40 W | 46.02 | 16.02 |
| 50 W | 46.99 | 16.99 |
| 80 W | 49.03 | 19.03 |
| 100 W | 50.00 | 20.00 |
| 320 W | 55.05 | 25.05 |
| 1 kW | 60.00 | 30.00 |
Worked examples
- 20 W to dBm: 10·log10(20) + 30 = 43.01 dBm, or 13.01 dBW. 10 W is 40.00 dBm. 2 W is 33.01 dBm. 40 W is 46.02 dBm. 50 W is 46.99 dBm. 80 W is 49.03 dBm.
- A +17 dBm driver into a 20 dB amplifier gives 17 + 20 = +37 dBm, which is 5.01 W. Adding dB to dBm works. A bare dB number has no dBm value until you add a reference level like that +17 dBm.
- 0 dBm is 1.000 mW. Into 50 Ω that is 0.2236 Vrms, and Vpp = 2√2 · Vrms.
- A +10 dB gain on a 0 dBm carrier is +10 dBm, which is 10 mW. The “+10 dB” is the ratio. The “dBm” values are the levels.
dBm/Hz to dBm/MHz: add 60 dB
Power in a flat band is the density plus 10·log10(B), with B in hertz. One megahertz is 10^6 Hz, so dBm/MHz = dBm/Hz + 60. −174 dBm/Hz is -114.00 dBm/MHz, and over a 20 MHz channel it is -100.99 dBm. kT at 290 K is -173.98 dBm/Hz, which is -113.98 dBm/MHz; a 1 MHz noise bandwidth is 60.00 dB-Hz, so kTB at 290 K is -113.98 dBm. Open the bandwidth tab at 20 MHz and type any density in dBm/Hz.
dBFS to dBm: add the full-scale power
dBm = dBFS + P_fs, where P_fs is the power of a sine whose peaks just reach the converter’s full-scale voltage, into the input impedance you state. The dBFS tab uses that sine convention and 50 Ω unless you type another impedance.
- 1.4 Vpp full scale into 100 Ω differential. Vrms = 1.4 / (2√2) = 0.4950 V, power = Vrms² / 100 = 2.45 mW = 3.89 dBm. That power is 0 dBFS. A tone at −6 dBFS is -2.11 dBm, 0.702 Vpp into the same 100 Ω. Open this example in the dBFS tab.
- Same 1.4 V peak as a square wave: RMS equals the peak (0.7 V), power is 4.9 mW, which is 6.90 dBm. That is 3.01 dB above the sine full scale. Use this shift only when the datasheet’s 0 dBFS is a square or a DC peak.
Mental math for dB conversions
Two rules cover most of the bench. 3 dB is twice the power (3.01 dB, to be exact) and 10 dB is ten times. So 20 W is 10 W plus 3 dB: 40 + 3 = 43 dBm. 80 W is three doublings above 10 W: 40 + 9 = 49 dBm, against 49.03 exact. The error grows by 0.01 dB per doubling, which I have never seen matter on a power meter. Voltage ratios use 20·log10, so 6 dB is twice the voltage. The full set of rules is in mental math for dB, power, and bandwidth.
Why “Hz to dB” is not a conversion
Hertz measures a tone or the width of a band. dB measures how many times larger one power is than another. The bandwidth tab does not turn 10 MHz into a dB level of a carrier. It computes 10·log10(B), with B in hertz, and adds that to -173.98 dBm/Hz. The -173.98 figure is kT at the IEEE noise temperature, 290 K, the same Boltzmann constant the cascade noise figure uses. The bench rule of thumb is −174 dBm/Hz; the extra 0.02 dB is the difference between that rounding and CODATA k at 290 K.
Density scales with the bandwidth unit, not with a carrier frequency. dBm/Hz + 30 dB = dBm/kHz. dBm/Hz + 60 dB = dBm/MHz. dBm/Hz + 90 dB = dBm/GHz. A 10 MHz CW tone still needs a power, in dBm or watts, before it has a level.
Checked against hand values: the cases, the tolerance and what the check does not cover.
FAQ
How do I convert dBm to dB?
dBm is a power level referred to 1 mW. dB is a ratio of two powers (or two voltages). There is no single conversion from a dBm number to a dB number. Subtract two levels: 20 dBm minus 13 dBm is 7 dB, a power ratio of about 5. A control that says “dBm to dB” is almost always asking for that difference, or for a ratio such as gain.
How many dBm is 10 W, 20 W, 40 W, or 80 W?
P(dBm) = 10·log10(P in watts) + 30, and dBW = dBm − 30. 2 W is 33.01 dBm (3.01 dBW). 10 W is 40.00 dBm. 20 W is 43.01 dBm (13.01 dBW). 40 W is 46.02 dBm (16.02 dBW). 50 W is 46.99 dBm (16.99 dBW). 80 W is 49.03 dBm (19.03 dBW). 320 W is 55.05 dBm. 1 mW is 0 dBm and 1 kW is 60 dBm.
How do I convert dBFS to dBm?
Add the converter’s full-scale sine power, in dBm, to the dBFS reading. This page takes 0 dBFS as a sine whose peak hits the full-scale voltage: Vrms = Vpp / (2√2). A 1.4 Vpp sine into 100 Ω is 3.89 dBm at 0 dBFS (Vrms 0.495 V), so −6 dBFS is -2.11 dBm. A square wave or a DC level at that same peak voltage is 3.01 dB higher than the sine. If a datasheet uses that peak convention, shift the full-scale power up by 3.01 dB before you add dBFS.
How do I convert dBm/Hz to dBm/MHz?
Add 60 dB. One megahertz is 10^6 hertz, and 10·log10(10^6) = 60. kT at 290 K is -173.98 dBm/Hz, which is -113.98 dBm/MHz. The same step turns a bandwidth into dB-Hz: 1 Hz is 0 dB-Hz and 1 MHz is 60.00 dB-Hz. Noise power in that bandwidth is the density plus the dB-Hz figure.
Can I convert MHz or Hz to dB?
No. A carrier at 10 MHz is not a power ratio, so it has no dB value. What does convert is a noise bandwidth: dB-Hz = 10·log10(B / 1 Hz). That number is then added to a density in dBm/Hz to get total noise power. “Hz to dB” and “MHz to dB” searches are usually this bandwidth step, or a mix-up with dBm/Hz.
How do I convert dBm to linear, or linear to dB?
A power ratio is 10^(dB/10). +10 dB is ×10 and +3 dB is ×1.995, about ×2. Going back is 10·log10 of the ratio. Voltage and field ratios use 20·log10, so +6 dB is ×2 in voltage and ×4 in power. Separately, 0 dBm is exactly 1 mW and +30 dBm is exactly 1 W. Do not run a dBm level through the ratio formula as if 0 dBm were a ratio of 1.