LC low-pass filter calculator, 1 GHz: 18.3 dB down at 2 GHz

Two 8 nH series inductors with a 6.4 pF shunt capacitor between them make a 1 GHz LC low-pass for 50 ohm: S21 is 3.08 dB down at 1 GHz, 18.3 dB down at 2 GHz, and the 3 dB point is 994.7 MHz. At 500 MHz it loses 0.07 dB with S11 at -18.0 dB, so the pass band is flat to well past half the cut-off.

Open in the simulator

Change this: halve L1, L2 and C1 together and the 3 dB point doubles, because each reactance goes with f times L or f times C.

Design another order or cutoff in the filter dialog, starting from this spec.

-40-30-20-1000.511.522.53GHzdB
S21S11Circles mark the table's numbers.
QuantityValueRead at
S21, pass band-0.07 dB500 MHz
S11, pass band-17.99 dB500 MHz
S21 at the design frequency-3.08 dB1 GHz
S21, stop band-18.27 dB2 GHz
3 dB frequency994.7 MHzwhere S21 is at half power

Every number here is the simulator's own, computed when the site was built from the same circuit the button opens. How the engine is checked.

The circuit

P1Z=50L1L=8nL2L=8nC1C=6.4pGND1P2Z=50

Ideal L and C, so the stop band keeps falling with frequency. A real inductor's self-resonance sets where the rejection stops growing; the bias tee example models one. Pads and traces are left out.

Other solved examples

Question about this circuit, or a correction?