LMR-600 cable loss

LMR-600 loses 0.31 dB per 10 m at 144 MHz and 1.42 dB at 2.4 GHz. The part is Times Microwave LMR-600, and every number here is fitted to the attenuation table on its datasheet. Drag the cursor or type a frequency, length and power to read the loss for your run.

LMR-600 loss for 10.0 m, matched

0.010.030.10.313101 MHz10 MHz100 MHz1 GHz10 GHzdB for 10.0 m2.40 GHz

Fit inside the printed tableExtrapolatedDatasheet rowsBand marks (the cursor snaps to them)

10.0 m at 2.40 GHz

Lost
1.42 dB
Out of 100 W
72.1 W
Delivered
72.1%

Neighbours at 2.40 GHz

  1. LMR-6001.42 dB
  2. Ecoflex 151.61 dB
  3. LMR-4002.17 dB

Rank 1 of 24 cables with a number at 2.40 GHz, lowest loss first.

Loss chart

Loss of LMR-600 against frequency, per 10 m and per 100 ft: 0.31 dB per 10 m at 144 MHz and 1.42 dB per 10 m at 2.4 GHz.
Matched loss from the fit, dB per 10 m on the left axis and per 100 ft on the right. Dots are the datasheet rows. The dashed part is past the printed table. The line stops at the usable limits.

Loss at 144 MHz to 5.8 GHz

FrequencydB per 10 mdB per 100 ftFrom
144 MHz0.310.95printed
433 MHz0.551.69printed
915 MHz0.832.52printed
1.09 GHz0.912.78printed
2.4 GHz1.424.32printed
5.8 GHz2.387.26printed

Printed means inside the datasheet table. A frequency outside the usable range names the limit instead of a number.

Cross-section

Jacket OD⌀ 15 mmDielectric⌀ 11.6 mmCentre conductor⌀ 4.47 mm5 mm
Drawn to scale from the printed diameters. The shield and jacket layers between the dielectric and the OD are not printed separately, so they share one ring.

Loss at each band

BanddB per 10 mdB per 100 ft
1.8 MHz0.030.10extrapolated
3.5 MHz0.050.14extrapolated
7 MHz0.070.20extrapolated
14 MHz0.090.29extrapolated
28 MHz0.130.41extrapolated
50 MHz0.180.55
144 MHz0.310.95
433 MHz0.551.69
915 MHz0.832.52
1.57 GHz1.123.41
2.4 GHz1.424.32
5.8 GHz2.387.26

Matched loss from the fit. A band past the printed table is marked extrapolated. A band outside the usable range names the limit instead of a number.

Datasheet table

MHzPrinted, dB/100 ftFitFit − printedMaker formula
300.40.4222+0.0220.4216
500.50.5479+0.0480.5472
15010.9653-0.0350.9643
2201.21.179-0.0211.178
4501.71.721+0.0211.720
9002.52.502+0.0022.501
15003.33.317+0.0173.316
18003.73.674-0.0263.673
20003.93.899-0.0013.899
25004.44.427+0.0274.428
58007.37.255-0.0457.262
80008.88.827+0.0278.837

Times Microwave LMR-600 datasheet, accessed 2026-10-11. Times Microwave LMR-600.

α (dB/m) = a·√f + b·f with f in GHz: a = 0.07850, b = 0.008443. Least squares over the 12 printed rows. RMS miss 0.028 dB/100 ft, largest 0.048 dB/100 ft at 50.0 MHz.

The sheet's own formula: dB/100 ft = 0.07555·√f + 0.00026·f with f in MHz.

Usable range and build

Printed from 30 MHz to 8 GHz. Usable from 1 MHz to 10.4 GHz; the top is set by the TE11 cutoff. TE11 cutoff 10.4 GHz, from the printed diameters and velocity factor.

Maker
Times Microwave Systems
Impedance
50 Ω
Velocity factor
0.87
Delay
3.83 ns/m
Dielectric
foam polyethylene
Centre conductor
0.176 in (4.47 mm)
Dielectric diameter
0.455 in (11.6 mm)
Jacket OD
14.99 mm
Rated maximum
not printed
Printed cutoff
not printed
Weight
0.131 lb/ft
Bend radius, installed
1.5 in (38.1 mm)
Bend radius, repeated
6 in (152 mm)
Shield
Aluminum tape plus tinned copper braid
  • Copies of the Times sheet disagree on velocity: most print 87%, some 85%. 87% reproduces the 10.3 GHz cutoff Times prints, so it is used here. The fit stops at the TE11 cutoff, about 10.4 GHz from the printed diameters.

Compare all cablesEvery cable's fit as CSV (CC BY 4.0)Question about this cable, or a correction?