RG-174 cable loss (Belden 8216)

Belden 8216 loses 3.45 dB per 10 m at 144 MHz and 19.8 dB at 2.4 GHz (extrapolated). The part is Belden 8216, RG-174, 26 AWG bare copper-covered steel, PE, and every number here is fitted to the attenuation table on its datasheet. Drag the cursor or type a frequency, length and power to read the loss for your run.

Belden 8216 loss for 10.0 m, matched

0.10.31310301001 MHz10 MHz100 MHz1 GHzdB for 10.0 m2.40 GHz

Fit inside the printed tableExtrapolatedDatasheet rowsBand marks (the cursor snaps to them)

10.0 m at 2.40 GHz

Lost
19.76 dB
Out of 100 W
1.06 W
Delivered
1.1%

Extrapolated. Extrapolated 2.4× past the last printed row at 1 GHz.

Neighbours at 2.40 GHz

  1. Taoglas RG-31614.61 dB
  2. Belden 8328415.50 dB
  3. Belden 821619.76 dB, extrapolated
  4. Belden 8326523.52 dB, extrapolated

Rank 23 of 24 cables with a number at 2.40 GHz, lowest loss first.

Loss chart

Loss of Belden 8216 (RG-174) against frequency, per 10 m and per 100 ft: 3.45 dB per 10 m at 144 MHz and 19.8 dB per 10 m at 2.4 GHz (extrapolated).
Matched loss from the fit, dB per 10 m on the left axis and per 100 ft on the right. Dots are the datasheet rows. The dashed part is past the printed table. The line stops at the usable limits.

Loss at 144 MHz to 5.8 GHz

FrequencydB per 10 mdB per 100 ftFrom
144 MHz3.4510.5printed
433 MHz6.5620.0printed
915 MHz10.431.8printed
1.09 GHz11.735.6extrapolated
2.4 GHz19.860.2extrapolated
5.8 GHzPast 4 GHz, 4× the last printed row

Printed means inside the datasheet table. A frequency outside the usable range names the limit instead of a number.

Cross-section

Jacket OD⌀ 2.79 mmDielectric⌀ 1.52 mmCentre conductor⌀ 0.483 mm1 mm
Drawn to scale from the printed diameters. The shield and jacket layers between the dielectric and the OD are not printed separately, so they share one ring.

Loss at each band

BanddB per 10 mdB per 100 ft
1.8 MHz0.341.04
3.5 MHz0.481.46
7 MHz0.682.08
14 MHz0.982.98
28 MHz1.414.30
50 MHz1.925.86
144 MHz3.4510.5
433 MHz6.5620.0
915 MHz10.431.8
1.57 GHz14.945.3extrapolated
2.4 GHz19.860.2extrapolated
5.8 GHzPast 4 GHz, 4× the last printed row

Matched loss from the fit. A band past the printed table is marked extrapolated. A band outside the usable range names the limit instead of a number.

Datasheet table

MHzPrinted, dB/100 ftFitFit − printed
11.90.7713-1.129
103.32.504-0.796
505.85.864+0.064
1008.48.572+0.172
20012.512.68+0.183
4001919.06+0.055
7002726.84-0.161
9003131.45+0.448
10003433.64-0.361

Belden 8216 technical data sheet, accessed 2026-10-11. Belden 8216, RG-174, 26 AWG bare copper-covered steel, PE.

α (dB/m) = a·√f + b·f with f in GHz: a = 0.7903, b = 0.3134. Least squares over the 9 printed rows. RMS miss 0.509 dB/100 ft, largest 1.129 dB/100 ft at 1.0 MHz.

Usable range and build

Printed from 1 MHz to 1 GHz. Usable from 1 MHz to 4 GHz; the top is set by the 4× the last printed row. TE11 cutoff 62.8 GHz, from the printed diameters and velocity factor.

Maker
Belden
RG name on the sheet
RG-174
Impedance
50 Ω
Velocity factor
0.66
Delay
5.05 ns/m
Dielectric
polyethylene
Centre conductor
0.019 in (0.483 mm)
Dielectric diameter
0.06 in (1.52 mm)
Jacket OD
2.79 mm
Rated maximum
not printed
Printed cutoff
not printed
Weight
8 lb/1000 ft
Bend radius, installed
1.1 in (27.9 mm)
Bend radius, repeated
not printed
Shield
Tinned copper braid, 90%
  • Attenuation is printed through 1000 MHz, so a 2.4 GHz or 5.8 GHz loss for this part is extrapolated. The sheet prints no maximum operating frequency.

Compare all cablesEvery cable's fit as CSV (CC BY 4.0)Question about this cable, or a correction?