RG-316 cable loss (Belden 83284)

Belden 83284 loses 3.36 dB per 10 m at 144 MHz and 15.5 dB at 2.4 GHz. The part is Belden 83284, RG-316, PTFE, commercial non-QPL (M17/113-RG316), and every number here is fitted to the attenuation table on its datasheet. Drag the cursor or type a frequency, length and power to read the loss for your run.

Belden 83284 loss for 10.0 m, matched

0.10.31310301001 MHz10 MHz100 MHz1 GHz10 GHzdB for 10.0 m2.40 GHz

Fit inside the printed tableExtrapolatedDatasheet rowsBand marks (the cursor snaps to them)

10.0 m at 2.40 GHz

Lost
15.50 dB
Out of 100 W
2.82 W
Delivered
2.8%

Neighbours at 2.40 GHz

  1. Belden 826213.48 dB, extrapolated
  2. Taoglas RG-31614.61 dB
  3. Belden 8328415.50 dB
  4. Belden 821619.76 dB, extrapolated
  5. Belden 8326523.52 dB, extrapolated

Rank 22 of 24 cables with a number at 2.40 GHz, lowest loss first.

Loss chart

Loss of Belden 83284 (RG-316) against frequency, per 10 m and per 100 ft: 3.36 dB per 10 m at 144 MHz and 15.5 dB per 10 m at 2.4 GHz.
Matched loss from the fit, dB per 10 m on the left axis and per 100 ft on the right. Dots are the datasheet rows. The dashed part is past the printed table. The line stops at the usable limits.

Loss at 144 MHz to 5.8 GHz

FrequencydB per 10 mdB per 100 ftFrom
144 MHz3.3610.3printed
433 MHz6.0118.3printed
915 MHz9.0227.5printed
1.09 GHz9.9330.3printed
2.4 GHz15.547.2printed
5.8 GHz26.179.6extrapolated

Printed means inside the datasheet table. A frequency outside the usable range names the limit instead of a number.

Cross-section

Jacket OD⌀ 2.5 mmDielectric⌀ 1.52 mmCentre conductor⌀ 0.508 mm1 mm
Drawn to scale from the printed diameters. The shield and jacket layers between the dielectric and the OD are not printed separately, so they share one ring.

Loss at each band

BanddB per 10 mdB per 100 ft
1.8 MHz0.361.10
3.5 MHz0.511.54
7 MHz0.722.19
14 MHz1.023.11
28 MHz1.454.42
50 MHz1.955.94
144 MHz3.3610.3
433 MHz6.0118.3
915 MHz9.0227.5
1.57 GHz12.237.2
2.4 GHz15.547.2
5.8 GHz26.179.6extrapolated

Matched loss from the fit. A band past the printed table is marked extrapolated. A band outside the usable range names the limit instead of a number.

Datasheet table

MHzPrinted, dB/100 ftFitFit − printed
11.20.8218-0.378
102.72.619-0.081
505.65.938+0.338
1008.38.485+0.185
2001212.17+0.173
40017.517.56+0.062
70023.723.74+0.039
90027.327.23-0.067
10002928.86-0.142
150036.536.16-0.340
200042.542.55+0.048
240047.247.23+0.029
300053.653.74+0.142

Belden 83284 technical data sheet, accessed 2026-10-11. Belden 83284, RG-316, PTFE, commercial non-QPL (M17/113-RG316).

α (dB/m) = a·√f + b·f with f in GHz: a = 0.8495, b = 0.09725. Least squares over the 13 printed rows. RMS miss 0.196 dB/100 ft, largest 0.378 dB/100 ft at 1.0 MHz.

Usable range and build

Printed from 1 MHz to 3 GHz. Usable from 1 MHz to 12 GHz; the top is set by the 4× the last printed row. TE11 cutoff 65.7 GHz, from the printed diameters and velocity factor.

Maker
Belden
RG name on the sheet
RG-316
Impedance
50 Ω
Velocity factor
0.7
Delay
4.77 ns/m
Dielectric
PTFE
Centre conductor
0.02 in (0.508 mm)
Dielectric diameter
0.06 in (1.52 mm)
Jacket OD
2.5 mm
Rated maximum
not printed
Printed cutoff
not printed
Weight
10 lb/1000 ft
Bend radius, installed
1 in (25.4 mm)
Bend radius, repeated
not printed
Shield
Silvered copper braid, 95%
  • Attenuation is printed through 3000 MHz, and the VSWR row is specified over 1 to 3000 MHz. 5.8 GHz is extrapolated.

Compare all cablesEvery cable's fit as CSV (CC BY 4.0)Question about this cable, or a correction?