SUCOFLEX 104 cable loss

SUCOFLEX 104 loses 0.88 dB per 10 m at 144 MHz (extrapolated) and 3.72 dB at 2.4 GHz. The part is Huber+Suhner SUCOFLEX_104, and every number here is fitted to the attenuation table on its datasheet. Drag the cursor or type a frequency, length and power to read the loss for your run.

SUCOFLEX 104 loss for 10.0 m, matched

0.10.313103010010 MHz100 MHz1 GHz10 GHzdB for 10.0 m2.40 GHz

Fit inside the printed tableExtrapolatedDatasheet rowsBand marks (the cursor snaps to them)

10.0 m at 2.40 GHz

Lost
3.72 dB
Out of 100 W
42.5 W
Delivered
42.5%

Neighbours at 2.40 GHz

  1. Aircell 73.42 dB
  2. SUCOFLEX 126E3.72 dB
  3. SUCOFLEX 1043.72 dB
  4. LMR-2404.16 dB
  5. Belden 82674.83 dB

Rank 7 of 24 cables with a number at 2.40 GHz, lowest loss first.

Loss chart

Loss of SUCOFLEX 104 against frequency, per 10 m and per 100 ft: 0.88 dB per 10 m at 144 MHz (extrapolated) and 3.72 dB per 10 m at 2.4 GHz.
Matched loss from the fit, dB per 10 m on the left axis and per 100 ft on the right. Dots are the datasheet rows. The dashed part is past the printed table. The line stops at the usable limits.

Loss at 144 MHz to 5.8 GHz

FrequencydB per 10 mdB per 100 ftFrom
144 MHz0.882.68extrapolated
433 MHz1.544.69printed
915 MHz2.266.88printed
1.09 GHz2.477.53printed
2.4 GHz3.7211.3printed
5.8 GHz5.9318.1printed

Printed means inside the datasheet table. A frequency outside the usable range names the limit instead of a number.

Cross-section

Jacket OD⌀ 5.5 mmDielectricnot printedCentre conductornot printed2 mm
Drawn to scale from the printed diameters. The shield and jacket layers between the dielectric and the OD are not printed separately, so they share one ring.

Loss at each band

BanddB per 10 mdB per 100 ft
1.8 MHzBelow the usable range, which starts at 6.7 MHz
3.5 MHzBelow the usable range, which starts at 6.7 MHz
7 MHz0.190.59extrapolated
14 MHz0.270.83extrapolated
28 MHz0.391.17extrapolated
50 MHz0.521.57extrapolated
144 MHz0.882.68extrapolated
433 MHz1.544.69
915 MHz2.266.88
1.57 GHz2.999.10
2.4 GHz3.7211.3
5.8 GHz5.9318.1

Matched loss from the fit. A band past the printed table is marked extrapolated. A band outside the usable range names the limit instead of a number.

Datasheet table

MHzPrinted, dB/mFitFit − printedMaker formula
2000.1040.1039-0.0000.1039
4000.1480.1477-0.0000.1477
6000.1820.1817-0.0000.1817
8000.2110.2106-0.0000.2106
10000.2360.2362+0.0000.2362
12000.2590.2595+0.0000.2595
14000.2810.2810-0.0000.2810
16000.3010.3011+0.0000.3012
18000.320.3201+0.0000.3201
20000.3380.3382+0.0000.3382
40000.4870.4866-0.0000.4866
60000.6040.6038-0.0000.6038
80000.7050.7049-0.0000.7048
100000.7950.7956+0.0010.7955
200001.1671.167-0.0001.167
265001.3681.368-0.0001.368

Huber+Suhner SUCOFLEX_104 data sheet, document PIM-P716, published 27 Oct 2023, accessed 2026-10-11. Huber+Suhner SUCOFLEX_104.

α (dB/m) = a·√f + b·f with f in GHz: a = 0.2290, b = 0.007127. Least squares over the 16 printed rows. RMS miss 0.000 dB/m, largest 0.001 dB/m at 10.0 GHz.

The sheet's own formula: dB/m = 0.2291·√f + 0.0071·f with f in GHz.

Usable range and build

Printed from 200 MHz to 26.5 GHz. Usable from 6.7 MHz to 26.5 GHz; the top is set by the rated maximum.

Maker
Huber+Suhner
Impedance
50 Ω
Velocity factor
0.77
Delay
4.33 ns/m
Dielectric
PTFE
Centre conductor
not printed
Dielectric diameter
not printed
Jacket OD
5.5 mm
Rated maximum
26.5 GHz
Printed cutoff
not printed
Weight
72 g/m
Bend radius, installed
16 mm
Bend radius, repeated
not printed
Shield
Silver-plated copper foil plus silver-plated copper braid
  • Sold as an assembly. Jacket on this sheet is 5.5 mm FEP. The armoured SUCOFLEX_104_G jacket is a different mechanical part and is not used here. Nominal attenuation only. Rated to 26.5 GHz, the last printed row.