Aircell 7 cable loss

Aircell 7 loses 0.70 dB per 10 m at 144 MHz and 3.42 dB at 2.4 GHz. The part is SSB-Electronic Aircell 7, item 6070, and every number here is fitted to the attenuation table on its datasheet. Drag the cursor or type a frequency, length and power to read the loss for your run.

Aircell 7 loss for 10.0 m, matched

0.010.030.10.313101 MHz10 MHz100 MHz1 GHzdB for 10.0 m2.40 GHz

Fit inside the printed tableExtrapolatedDatasheet rowsBand marks (the cursor snaps to them)

10.0 m at 2.40 GHz

Lost
3.42 dB
Out of 100 W
45.5 W
Delivered
45.5%

Neighbours at 2.40 GHz

  1. LMR-4002.17 dB
  2. Ecoflex 102.20 dB
  3. Aircell 73.42 dB
  4. SUCOFLEX 126E3.72 dB
  5. SUCOFLEX 1043.72 dB

Rank 5 of 24 cables with a number at 2.40 GHz, lowest loss first.

Loss chart

Loss of Aircell 7 against frequency, per 10 m and per 100 ft: 0.70 dB per 10 m at 144 MHz and 3.42 dB per 10 m at 2.4 GHz.
Matched loss from the fit, dB per 10 m on the left axis and per 100 ft on the right. Dots are the datasheet rows. The dashed part is past the printed table. The line stops at the usable limits.

Loss at 144 MHz to 5.8 GHz

FrequencydB per 10 mdB per 100 ftFrom
144 MHz0.702.12printed
433 MHz1.273.86printed
915 MHz1.935.89printed
1.09 GHz2.146.51printed
2.4 GHz3.4210.4printed
5.8 GHz5.9718.2printed

Printed means inside the datasheet table. A frequency outside the usable range names the limit instead of a number.

Cross-section

Jacket OD⌀ 7.3 mmDielectric⌀ 5 mmCentre conductor⌀ 1.9 mm2 mm
Drawn to scale from the printed diameters. The shield and jacket layers between the dielectric and the OD are not printed separately, so they share one ring.

Loss at each band

BanddB per 10 mdB per 100 ft
1.8 MHz0.070.22extrapolated
3.5 MHz0.100.31extrapolated
7 MHz0.150.44
14 MHz0.210.63
28 MHz0.300.90
50 MHz0.401.22
144 MHz0.702.12
433 MHz1.273.86
915 MHz1.935.89
1.57 GHz2.658.09
2.4 GHz3.4210.4
5.8 GHz5.9718.2

Matched loss from the fit. A band past the printed table is marked extrapolated. A band outside the usable range names the limit instead of a number.

Datasheet table

MHzPrinted, dB/100 mFitFit − printed
51.521.230-0.290
102.091.748-0.342
504.293.997-0.293
1005.975.745-0.225
1447.226.970-0.250
2008.598.310-0.280
30010.6410.35-0.288
43212.9212.65-0.270
50013.9813.72-0.259
80018.0517.89-0.165
100020.4420.33-0.110
129623.623.64+0.043
150025.7325.77+0.040
180028.528.73+0.225
200030.2930.60+0.314
240033.8234.19+0.366
300038.8439.22+0.382
400046.6646.98+0.324
500054.1954.20+0.009
600061.6661.03-0.635

SSB-Electronic Aircell 7 data sheet (item 6070), accessed 2026-10-25. SSB-Electronic Aircell 7, item 6070.

α (dB/m) = a·√f + b·f with f in GHz: a = 0.1717, b = 0.03162. Least squares over the 20 printed rows. RMS miss 0.290 dB/100 m, largest 0.635 dB/100 m at 6.00 GHz.

Usable range and build

Printed from 5 MHz to 6 GHz. Usable from 1 MHz to 6 GHz; the top is set by the rated maximum. TE11 cutoff 23.5 GHz, from the printed diameters and velocity factor.

Maker
SSB-Electronic
Impedance
50 Ω
Velocity factor
0.85
Delay
3.92 ns/m
Dielectric
foam polyethylene
Centre conductor
1.9 mm
Dielectric diameter
5 mm
Jacket OD
7.3 mm
Rated maximum
6.00 GHz
Printed cutoff
not printed
Weight
70 kg/km
Bend radius, installed
29.2 mm
Bend radius, repeated
58.4 mm
Shield
Copper foil plus 85% bare copper braid
  • Typical attenuation at 20°C. Bend radius is printed as 4× (single) and 8× (repeated) the 7.3 mm diameter. The 5 and 10 MHz rows sit about 10% below the fit, where the stranded center conductor stops following √f. The sheet prints no date or revision.

Compare all cablesEvery cable's fit as CSV (CC BY 4.0)Question about this cable, or a correction?