LMR-240 cable loss

LMR-240 loses 0.97 dB per 10 m at 144 MHz and 4.16 dB at 2.4 GHz. The part is Times Microwave LMR-240, and every number here is fitted to the attenuation table on its datasheet. Drag the cursor or type a frequency, length and power to read the loss for your run.

LMR-240 loss for 10.0 m, matched

0.010.11101001 MHz10 MHz100 MHz1 GHz10 GHzdB for 10.0 m2.40 GHz

Fit inside the printed tableExtrapolatedDatasheet rowsBand marks (the cursor snaps to them)

10.0 m at 2.40 GHz

Lost
4.16 dB
Out of 100 W
38.4 W
Delivered
38.4%

Neighbours at 2.40 GHz

  1. SUCOFLEX 126E3.72 dB
  2. SUCOFLEX 1043.72 dB
  3. LMR-2404.16 dB
  4. Belden 82674.83 dB
  5. H1554.91 dB

Rank 8 of 24 cables with a number at 2.40 GHz, lowest loss first.

Loss chart

Loss of LMR-240 against frequency, per 10 m and per 100 ft: 0.97 dB per 10 m at 144 MHz and 4.16 dB per 10 m at 2.4 GHz.
Matched loss from the fit, dB per 10 m on the left axis and per 100 ft on the right. Dots are the datasheet rows. The dashed part is past the printed table. The line stops at the usable limits.

Loss at 144 MHz to 5.8 GHz

FrequencydB per 10 mdB per 100 ftFrom
144 MHz0.972.96printed
433 MHz1.705.19printed
915 MHz2.517.64printed
1.09 GHz2.758.37printed
2.4 GHz4.1612.7printed
5.8 GHz6.6820.4printed

Printed means inside the datasheet table. A frequency outside the usable range names the limit instead of a number.

Cross-section

Jacket OD⌀ 6.1 mmDielectric⌀ 3.81 mmCentre conductor⌀ 1.42 mm2 mm
Drawn to scale from the printed diameters. The shield and jacket layers between the dielectric and the OD are not printed separately, so they share one ring.

Loss at each band

BanddB per 10 mdB per 100 ft
1.8 MHz0.110.33extrapolated
3.5 MHz0.150.46extrapolated
7 MHz0.210.64extrapolated
14 MHz0.300.91extrapolated
28 MHz0.421.29extrapolated
50 MHz0.571.73
144 MHz0.972.96
433 MHz1.705.19
915 MHz2.517.64
1.57 GHz3.3310.1
2.4 GHz4.1612.7
5.8 GHz6.6820.4

Matched loss from the fit. A band past the printed table is marked extrapolated. A band outside the usable range names the limit instead of a number.

Datasheet table

MHzPrinted, dB/100 ftFitFit − printedMaker formula
301.31.339+0.0391.336
501.71.733+0.0331.728
15033.022+0.0223.014
2203.73.672-0.0283.663
4505.35.295-0.0055.284
9007.67.575-0.0257.559
15009.99.889-0.0119.871
180010.910.88-0.01610.86
200011.511.51+0.00611.49
250012.912.95+0.05012.93
580020.420.37-0.02820.35
800024.324.31+0.01224.29

Times Microwave LMR-240 datasheet, accessed 2026-10-11. Times Microwave LMR-240.

α (dB/m) = a·√f + b·f with f in GHz: a = 0.2518, b = 0.01067. Least squares over the 12 printed rows. RMS miss 0.026 dB/100 ft, largest 0.050 dB/100 ft at 2.50 GHz.

The sheet's own formula: dB/100 ft = 0.24208·√f + 0.00033·f with f in MHz.

Usable range and build

Printed from 30 MHz to 8 GHz. Usable from 1 MHz to 30.6 GHz; the top is set by the TE11 cutoff. TE11 cutoff 30.6 GHz, from the printed diameters and velocity factor.

Maker
Times Microwave Systems
Impedance
50 Ω
Velocity factor
0.84
Delay
3.97 ns/m
Dielectric
foam polyethylene
Centre conductor
0.056 in (1.42 mm)
Dielectric diameter
0.15 in (3.81 mm)
Jacket OD
6.1 mm
Rated maximum
not printed
Printed cutoff
not printed
Weight
0.034 lb/ft
Bend radius, installed
0.75 in (19 mm)
Bend radius, repeated
2.5 in (63.5 mm)
Shield
Aluminum tape plus tinned copper braid
  • Attenuation is the typical 25°C, VSWR 1.0 table through 8000 MHz.

Compare all cablesEvery cable's fit as CSV (CC BY 4.0)Question about this cable, or a correction?