Ecoflex 10 cable loss

Ecoflex 10 loses 0.49 dB per 10 m at 144 MHz and 2.20 dB at 2.4 GHz. The part is SSB-Electronic Ecoflex 10, item 6080, and every number here is fitted to the attenuation table on its datasheet. Drag the cursor or type a frequency, length and power to read the loss for your run.

Ecoflex 10 loss for 10.0 m, matched

0.010.030.10.313101 MHz10 MHz100 MHz1 GHzdB for 10.0 m2.40 GHz

Fit inside the printed tableExtrapolatedDatasheet rowsBand marks (the cursor snaps to them)

10.0 m at 2.40 GHz

Lost
2.20 dB
Out of 100 W
60.2 W
Delivered
60.2%

Neighbours at 2.40 GHz

  1. Ecoflex 151.61 dB
  2. LMR-4002.17 dB
  3. Ecoflex 102.20 dB
  4. Aircell 73.42 dB
  5. SUCOFLEX 126E3.72 dB

Rank 4 of 24 cables with a number at 2.40 GHz, lowest loss first.

Loss chart

Loss of Ecoflex 10 against frequency, per 10 m and per 100 ft: 0.49 dB per 10 m at 144 MHz and 2.20 dB per 10 m at 2.4 GHz.
Matched loss from the fit, dB per 10 m on the left axis and per 100 ft on the right. Dots are the datasheet rows. The dashed part is past the printed table. The line stops at the usable limits.

Loss at 144 MHz to 5.8 GHz

FrequencydB per 10 mdB per 100 ftFrom
144 MHz0.491.49printed
433 MHz0.872.64printed
915 MHz1.293.94printed
1.09 GHz1.424.34printed
2.4 GHz2.206.71printed
5.8 GHz3.6611.2printed

Printed means inside the datasheet table. A frequency outside the usable range names the limit instead of a number.

Cross-section

Jacket OD⌀ 10.2 mmDielectric⌀ 7.2 mmCentre conductor⌀ 2.85 mm2 mm
Drawn to scale from the printed diameters. The shield and jacket layers between the dielectric and the OD are not printed separately, so they share one ring.

Loss at each band

BanddB per 10 mdB per 100 ft
1.8 MHz0.050.16extrapolated
3.5 MHz0.070.23extrapolated
7 MHz0.100.32
14 MHz0.150.45
28 MHz0.210.64
50 MHz0.280.86
144 MHz0.491.49
433 MHz0.872.64
915 MHz1.293.94
1.57 GHz1.745.31
2.4 GHz2.206.71
5.8 GHz3.6611.2

Matched loss from the fit. A band past the printed table is marked extrapolated. A band outside the usable range names the limit instead of a number.

Datasheet table

MHzPrinted, dB/100 mFitFit − printed
50.760.8834+0.123
101.141.253+0.113
502.662.833+0.173
1003.84.041+0.241
1444.664.877+0.217
2005.515.783+0.273
3006.947.147+0.207
4328.468.661+0.201
5009.129.358+0.238
80011.8812.03+0.153
100013.4913.58+0.086
129615.6815.64-0.041
150017.0116.95-0.062
180018.9118.75-0.162
200020.1419.88-0.258
240022.4222.02-0.397
300025.3724.99-0.379
400029.5529.48-0.068
500033.4433.58+0.136
600037.0537.39+0.340

SSB-Electronic Ecoflex 10 data sheet (item 6080), accessed 2026-10-25. SSB-Electronic Ecoflex 10, item 6080.

α (dB/m) = a·√f + b·f with f in GHz: a = 0.1241, b = 0.01165. Least squares over the 20 printed rows. RMS miss 0.218 dB/100 m, largest 0.397 dB/100 m at 2.40 GHz.

Usable range and build

Printed from 5 MHz to 6 GHz. Usable from 1 MHz to 6 GHz; the top is set by the rated maximum. TE11 cutoff 16.1 GHz, from the printed diameters and velocity factor.

Maker
SSB-Electronic
Impedance
50 Ω
Velocity factor
0.85
Delay
3.92 ns/m
Dielectric
foam polyethylene
Centre conductor
2.85 mm
Dielectric diameter
7.2 mm
Jacket OD
10.2 mm
Rated maximum
6.00 GHz
Printed cutoff
not printed
Weight
129 kg/km
Bend radius, installed
40.8 mm
Bend radius, repeated
81.6 mm
Shield
Copper foil plus 75% bare copper braid
  • Typical attenuation at 20°C. Bend radius is printed as 4× (single) and 8× (repeated) the 10.2 mm diameter. The 5 MHz row sits about 8% above the fit. The sheet prints no date or revision.

Compare all cablesEvery cable's fit as CSV (CC BY 4.0)Question about this cable, or a correction?