FET frequency doubler by harmonic balance: 2.86 dBm at 2 GHz from 1 GHz, 0.8 dB conversion gain

Biased at -1 V, pinch-off, the FET conducts on half of each cycle and puts 2.86 dBm at 2 GHz into 50 ohm from 2.04 dBm at 1 GHz, a conversion gain of 0.82 dB. With no filter the 1 GHz feedthrough is 8.97 dBm, 6.1 dB above the wanted output, so a real doubler needs a 1 GHz trap or a band-pass at 2 GHz on the drain.

Open in the simulator

Change this: move V1 from -1 V to -0.5 V. The FET then conducts all cycle, so the 2 GHz output falls and the 1 GHz grows: it is an amplifier again.

-30-20-100101234567GHzdBm9.02.9
2 f0, the outputf0 feedthroughOther harmonicsPower into the load at each harmonic.
QuantityValueRead at
Output at 2 f02.858 dBm2 GHz, 2.04 dBm in
Conversion gain0.817 dB1 GHz in, 2 GHz out
Fundamental feedthrough, relative to 2 f06.11 dBc1 GHz
Third harmonic, relative to 2 f0-14.46 dBc3 GHz
Fundamental feedthrough8.966 dBm1 GHz

Every number here is the simulator's own, computed when the site was built from the same circuit the button opens. How the engine is checked.

The circuit

P1Z=50V1V=-1Q1VTO=-1T1Z=50V2V=3GND1GND2gd

How it is checked

This is one of the five reference circuits the harmonic balance engine was built against, at ngspice's own drive, 2.04 dBm: 0.8 V peak behind 50 ohm. ngspice 47 runs the same circuit as a transient for 20 periods, and an FFT of the last 4 reads the steady state at each harmonic. The rule is 1e-4 of the fundamental plus 1e-3 of the harmonic itself at every harmonic to the seventh, about a hundredth of a dB on Pout and gain, and the site's tests fail if a number on this page moves outside it.

The Statz card is IndieRF's illustrative values, not a real part, and the drain sees a plain 50 ohm from 3 V at every harmonic, with no output filter or matching. The sweep stops at 5 dBm, the last step where 32 harmonics hold the half-wave drain current to 1e-3 of the fundamental.

Other solved examples

Question about this circuit, or a correction?