Load-pull simulation of a FET stage at 1 GHz: 15.23 dBm at the best load, 0.86 dB over 50 ohm

At -0.46 dBm available, this FET stage delivers 15.23 dBm into Γ_L = 0.340 + 0.086j, 0.86 dB more than the 14.37 dBm it puts into 50 ohm. The load of most PAE is elsewhere: 41.3 % at Γ_L = 0.590 + 0.087j, giving up 0.58 dB of output for 4.1 more points of PAE, so a real match sits between the two contours. Into 50 ohm the PAE is 25.7 %. Both best loads put |Γin| just over 1 at -0.46 dBm, 1.009 and 1.006: the gate shows negative resistance at 1 GHz, so the input returns more power than it receives. A 50 ohm source is still stable, but a real design would add stabilization at the input.

Open in the simulator

Change this: lower V2 from 4 V to 3 V. Less drain swing: the Pdel contours shrink and the best load moves.

load-pull simulation harmonic balance: Pdel and PAE contours at -0.46 dBm available40 %35 %30 %25 %20 %14.2 dBm13.2 dBm12.2 dBm11.2 dBm10.2 dBm50 ΩPAE 41.3 %Pdel 15.23 dBm
Pdel, 1 dB apartPAE, 5-point stepsAt -0.46 dBm available. Dots are the 113 grid loads; the diamond and the square are the loads of most Pdel and most PAE.
QuantityValueRead at
Most delivered power15.228 dBm1 GHz, -0.46 dBm in
Load of most Pdel, Re Γ_L0.3398on 50 ohm
Load of most Pdel, Im Γ_L0.0858on 50 ohm
PAE at that load37.20 %-0.46 dBm in
Most PAE41.28 %1 GHz, -0.46 dBm in
Load of most PAE, Re Γ_L0.5901on 50 ohm
Load of most PAE, Im Γ_L0.0868on 50 ohm
Pdel at that load14.645 dBm-0.46 dBm in
|Γin| at the load of most Pdel1.0089-0.46 dBm in
|Γin| at the load of most PAE1.0057-0.46 dBm in
Pout into 50 ohm14.368 dBmno tuner
PAE into 50 ohm25.66 %no tuner
Most Pdel over Pout into 50 ohm0.860 dB-0.46 dBm in
AM-PM into 50 ohm-0.315 °-0.46 dBm against the lowest drive

Every number here is the simulator's own, computed when the site was built from the same circuit the button opens. How the engine is checked.

The circuit

P1Z=50V1V=-0.5Q1VTO=-1T1Z=50V2V=4GND1GND2gd

How it is checked

This is the Statz FET stage the load-pull was built against. ngspice 47 runs it as a transient with a physical load network on the drain, six networks at -26.48 dBm and -0.46 dBm, and the engine sets its tuner to each network's Γ at every harmonic: delivered power meets ngspice within three ten-thousandths of a dB, PAE within 0.002 points and AM-PM within 0.012°. The contour lines on the chart are drawn between grid loads; at small signal they are the textbook constant-gain circles, and the site's tests hold every drawn point to its circle within the interpolation error, 0.023 in Γ on this 13-point grid and four times less at half the step.

The Statz card is IndieRF's illustrative values, not a real part. The tuner sets Γ_L at 1 GHz only, and the harmonics see 50 ohm; a real tuner also has loss, which this one does not. Gate bias is -0.5 V, the drain supply 4 V, and the input stays at 50 ohm, so G_T includes the input mismatch. At -0.46 dBm, 16 harmonics truncate the waveform at 10 of the 113 loads, at the two ends of the real axis, and the run says so; each delivers more than 5 dB under the most, outside every Pdel contour drawn.

Other solved examples

Question about this circuit, or a correction?