RG-400 cable loss (Harbour)

Harbour RG-400 loses 1.63 dB per 10 m at 144 MHz and 7.75 dB at 2.4 GHz. The part is Harbour Industries M17/128-RG400, MIL-DTL-17 QPL, and every number here is fitted to the attenuation table on its datasheet. Drag the cursor or type a frequency, length and power to read the loss for your run.

Harbour RG-400 loss for 10.0 m, matched

0.10.313103010010 MHz100 MHz1 GHz10 GHzdB for 10.0 m2.40 GHz

Fit inside the printed tableExtrapolatedDatasheet rowsBand marks (the cursor snaps to them)

10.0 m at 2.40 GHz

Lost
7.75 dB
Out of 100 W
16.8 W
Delivered
16.8%

Neighbours at 2.40 GHz

  1. Belden 92586.36 dB, extrapolated
  2. Belden 841427.00 dB
  3. Harbour RG-4007.75 dB
  4. EZ 8610.02 dB
  5. Hand-Flex 08611.42 dB

Rank 16 of 24 cables with a number at 2.40 GHz, lowest loss first.

Loss chart

Loss of Harbour RG-400 against frequency, per 10 m and per 100 ft: 1.63 dB per 10 m at 144 MHz and 7.75 dB per 10 m at 2.4 GHz.
Matched loss from the fit, dB per 10 m on the left axis and per 100 ft on the right. Dots are the datasheet rows. The dashed part is past the printed table. The line stops at the usable limits.

Loss at 144 MHz to 5.8 GHz

FrequencydB per 10 mdB per 100 ftFrom
144 MHz1.634.95printed
433 MHz2.938.93printed
915 MHz4.4413.5printed
1.09 GHz4.9014.9printed
2.4 GHz7.7523.6printed
5.8 GHz13.340.6printed

Printed means inside the datasheet table. A frequency outside the usable range names the limit instead of a number.

Cross-section

Jacket OD⌀ 4.95 mmDielectric⌀ 2.95 mmCentre conductor⌀ 0.975 mm2 mm
Drawn to scale from the printed diameters. The shield and jacket layers between the dielectric and the OD are not printed separately, so they share one ring.

Loss at each band

BanddB per 10 mdB per 100 ft
1.8 MHzBelow the usable range, which starts at 3.3 MHz
3.5 MHz0.240.74extrapolated
7 MHz0.341.05extrapolated
14 MHz0.491.49extrapolated
28 MHz0.692.12extrapolated
50 MHz0.942.85extrapolated
144 MHz1.634.95
433 MHz2.938.93
915 MHz4.4413.5
1.57 GHz6.0518.4
2.4 GHz7.7523.6
5.8 GHz13.340.6

Matched loss from the fit. A band past the printed table is marked extrapolated. A band outside the usable range names the limit instead of a number.

Datasheet table

MHzPrinted, dB/100 ftFitFit − printedMaker formula
1004.14.091-0.0094.088
4008.68.557-0.0438.552
100014.214.22+0.02014.21
240023.623.63+0.02623.62
50003736.98-0.01636.98
1000057.857.80+0.00157.80

Harbour Industries MIL-DTL-17 coaxial cables data sheet, accessed 2026-10-25. Harbour Industries M17/128-RG400, MIL-DTL-17 QPL.

α (dB/m) = a·√f + b·f with f in GHz: a = 0.4050, b = 0.06158. Least squares over the 6 printed rows. RMS miss 0.023 dB/100 ft, largest 0.043 dB/100 ft at 400 MHz.

The sheet's own formula: dB/100 ft = 0.39·√f + 0.00188·f with f in MHz.

Usable range and build

Printed from 100 MHz to 10 GHz. Usable from 3.3 MHz to 12.4 GHz; the top is set by the rated maximum. TE11 cutoff 34.1 GHz, from the printed diameters and velocity factor.

Maker
Harbour Industries
RG name on the sheet
RG-400
Impedance
50 Ω
Velocity factor
0.7
Delay
4.77 ns/m
Dielectric
PTFE
Centre conductor
0.0384 in (0.975 mm)
Dielectric diameter
0.116 in (2.95 mm)
Jacket OD
4.95 mm
Rated maximum
12.4 GHz
Printed cutoff
not printed
Weight
50 lb/1000 ft
Bend radius, installed
1 in (25.4 mm)
Bend radius, repeated
not printed
Shield
Two silver-plated copper braids
  • Attenuation is Harbour's typical column. The MIL-DTL-17 maximum is higher (18.1 dB/100 ft at 1 GHz against 14.2 typical). The PDF prints no velocity factor. The 70% here is from Harbour's M17/128-RG400 product page. The sheet prints no revision or date.

Compare all cablesEvery cable's fit as CSV (CC BY 4.0)Question about this cable, or a correction?