SUCOFLEX 102 cable loss

SUCOFLEX 102 loses 1.41 dB per 10 m at 144 MHz (extrapolated) and 5.90 dB at 2.4 GHz. The part is Huber+Suhner SUCOFLEX_102, item 22511794, and every number here is fitted to the attenuation table on its datasheet. Drag the cursor or type a frequency, length and power to read the loss for your run.

SUCOFLEX 102 loss for 10.0 m, matched

0.10.313103010010 MHz100 MHz1 GHz10 GHzdB for 10.0 m2.40 GHz

Fit inside the printed tableExtrapolatedDatasheet rowsBand marks (the cursor snaps to them)

10.0 m at 2.40 GHz

Lost
5.90 dB
Out of 100 W
25.7 W
Delivered
25.7%

Neighbours at 2.40 GHz

  1. Belden 82674.83 dB
  2. H1554.91 dB
  3. SUCOFLEX 1025.90 dB
  4. SR 1415.99 dB
  5. LMR-1956.10 dB

Rank 11 of 24 cables with a number at 2.40 GHz, lowest loss first.

Loss chart

Loss of SUCOFLEX 102 against frequency, per 10 m and per 100 ft: 1.41 dB per 10 m at 144 MHz (extrapolated) and 5.90 dB per 10 m at 2.4 GHz.
Matched loss from the fit, dB per 10 m on the left axis and per 100 ft on the right. Dots are the datasheet rows. The dashed part is past the printed table. The line stops at the usable limits.

Loss at 144 MHz to 5.8 GHz

FrequencydB per 10 mdB per 100 ftFrom
144 MHz1.414.31extrapolated
433 MHz2.477.51printed
915 MHz3.6011.0printed
1.09 GHz3.9412.0printed
2.4 GHz5.9018.0printed
5.8 GHz9.3228.4printed

Printed means inside the datasheet table. A frequency outside the usable range names the limit instead of a number.

Cross-section

Jacket OD⌀ 4 mmDielectricnot printedCentre conductornot printed1 mm
Drawn to scale from the printed diameters. The shield and jacket layers between the dielectric and the OD are not printed separately, so they share one ring.

Loss at each band

BanddB per 10 mdB per 100 ft
1.8 MHzBelow the usable range, which starts at 6.7 MHz
3.5 MHzBelow the usable range, which starts at 6.7 MHz
7 MHz0.310.94extrapolated
14 MHz0.441.34extrapolated
28 MHz0.621.89extrapolated
50 MHz0.832.53extrapolated
144 MHz1.414.31extrapolated
433 MHz2.477.51
915 MHz3.6011.0
1.57 GHz4.7514.5
2.4 GHz5.9018.0
5.8 GHz9.3228.4

Matched loss from the fit. A band past the printed table is marked extrapolated. A band outside the usable range names the limit instead of a number.

Datasheet table

MHzPrinted, dB/mFitFit − printedMaker formula
2000.1670.1669-0.0000.1669
4000.2370.2368-0.0000.2368
6000.2910.2908-0.0000.2909
8000.3370.3366-0.0000.3366
10000.3770.3771+0.0000.3771
12000.4140.4138-0.0000.4138
14000.4480.4477-0.0000.4477
16000.4790.4793+0.0000.4794
18000.5090.5091+0.0000.5092
20000.5370.5374+0.0000.5375
40000.7680.7683+0.0000.7684
60000.9490.9488-0.0000.9489
80001.1031.103+0.0001.103
100001.2411.241-0.0001.241
200001.7971.797-0.0001.797
400002.6242.624+0.0002.624
460002.8362.836+0.0002.836

Huber+Suhner SUCOFLEX_102 data sheet, document PIM-P723, published 27 Oct 2023, accessed 2026-10-25. Huber+Suhner SUCOFLEX_102, item 22511794.

α (dB/m) = a·√f + b·f with f in GHz: a = 0.3700, b = 0.007106. Least squares over the 17 printed rows. RMS miss 0.000 dB/m, largest 0.000 dB/m at 800 MHz.

The sheet's own formula: dB/m = 0.37·√f + 0.0071·f with f in GHz.

Usable range and build

Printed from 200 MHz to 46 GHz. Usable from 6.7 MHz to 46 GHz; the top is set by the rated maximum.

Maker
Huber+Suhner
Impedance
50 Ω
Velocity factor
0.77
Delay
4.33 ns/m
Dielectric
PTFE
Centre conductor
not printed
Dielectric diameter
not printed
Jacket OD
4 mm
Rated maximum
46.0 GHz
Printed cutoff
not printed
Weight
40 g/m
Bend radius, installed
12 mm
Bend radius, repeated
not printed
Shield
Silver-plated copper foil plus silver-plated copper braid
  • Sold as an assembly. Nominal attenuation at 25°C. Rated to 46 GHz, the last printed row. The sheet prints the dynamic bend radius only as under 20 mm, so the 12 mm static figure is used.

Compare all cablesEvery cable's fit as CSV (CC BY 4.0)Question about this cable, or a correction?